Braeburn 140424 Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Braeburn 140424. Braeburn 140424 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
®
140424
2 Zone
Expander Panel
Installer Manual
140424-100-02
Warning
Read all of the instructions before proceeding
Can cause electrical shock or equipment damage. Always turn off power to the heating/air
conditioning system prior to installing or adjusting the Zone Panel Expander. Complete the
wiring for the main panel and expansion panel before applying transformer power.
This panel is designed for professional installation, and is to be installed and configured as
described in this manual. Any other use is not recommended and will void the warranty.
Install disconnect and overload protection on circuits as required by code authorities having
jurisdiction for the installation.
Voltage Hazard
Caution
For Use with Braeburn
Model 140404
Store this manual for future reference.
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - Installer Manual

®140424 2 Zone Expander Panel Installer Manual140424-100-02 WarningRead all of the instructions before proceedingCan cause electrical shock or equipme

Pagina 2 - Table of Contents

Add Zones to Main Panel 5The 4 Zone Expandable Panel can be expanded to up to 32 zones with four zones on the main panel and 28 total expansion zones.

Pagina 3 - Suitable Mounting Locations

Error Conditions 7The Main Panel continually monitors various components of the zone system and will display a message when the following Expander Pan

Pagina 4 - Wiring the Panel

Store this manual for future reference.Limited WarrantyWhen installed by a professional contractor, this product is backed by a 5 year limited warrant

Pagina 5 - Terminal

Specifications 1 Storage temperature: -40˚–167˚F (-40˚–75˚C)Operating temperature: -22˚–167˚F (-30˚–75˚C)Voltage: 24 VAC, Nominal 60Hz 18-30 VAC Maxi

Pagina 6 - Example Wiring Options

Suitable Mounting Locations 2 Mount the Zone Panel Expander near the Main Panel. If desired, the expander panel can be mounted up to 500 feet from the

Pagina 7 - Thermostat Wiring

Wiring the Panel 3 Always turn off power to the heating/air conditioning system prior to installing or adjusting the Zone Panel Expander. Use the foll

Pagina 8 - installer settings

The expansion zones may be wired to either the top or bottom communication terminals on the main panel or to the top or bottom communication terminals

Pagina 9 - Zone Addressing

Daisy Chain Zones Located Remote to Main Panel (Up to 500 Feet)Main PanelExpander PanelZones 5-6Expander PanelAs NeededExpander PanelZones 7-8500 Ft.

Pagina 10 - Operation

Damper Wiring3.1 Install the system dampers using the instructions provided by the manufacturer. Connect the dampers to the zone panel expander as sho

Pagina 11 - Error Conditions

HEAT PUMP THERMOSTATS 1 HEAT / 1 COOL - No Auxiliary Heat R 24 VAC Power O/B Changeover Valve [Note 2] Y1 Compressor Call (1st Stage Heating/Coolin

Pagina 12 - Limited Warranty

Transformer Wiring 3.3 24V24CCCHOTDedicatedZoning TransformerZonePanelZone Addressing 4 Use the following instructions to identify the zones on the zo